Computerized Gas and PM Mass/Emissions Test Cell

Model - Smart 2100 xxx
 
Analyzer Rack Accuracy / Performance
C0: 0 - 3000/5000 PPM 5/10% vol max. 2.0 % Abs. NDIR
C02: 0-5/10/20% vol max. 2.0 % Abs. NDIR
HC: 0-2000/20000 PPM max. 2.0 % Abs. NDIR
THC: 0-2000/10000 PPM max. 2.0 % Abs. FID
CH4: 0-500/5000 PPM max. 2.0 % Abs. NDIR
N20: 0-200/1000 PPM max. 2.0 % Abs. NDIR
NO,NO2: 0-1000 PPM max. 2.0 % Abs CLD
S02: 0-2000/5000 PPM max. 2.0 % Abs. NDIR
Opacity 0 - 100% +/- 0.5% Abs. Optical
PM [gr/km] +/- 1% Gravimetric
Soot density [gr/m3] +/- 0.5% Abs.
Full/Partial Flow CVS Accuracy / Performance
Venturi Critical Flow .. .......0-450 cfm max. +/- 1% Abs.
Dilution Tunnel 4" dia. x 132"
Blower - Spencer 450 cfm
Sample Flow Rate 10-15 lpm
CFO Pressure 0-100 PSI +/-0. 1 % Abs.
CFO Temp. 0-100 deg.C +/-0. 1 % Abs.
International Standards
ASTM 15/25, 25/50
EURO II,III 96/69/EC , 98/69/EC
EU 15/40 97

 

 

TOYOTA FRICTION TESTER
CNG Emissions with Chassis Dynamometer Test Cell

Model - Smart MH 6000
PIC2

 

HSS
CNG Cylinder Hyrostatic Computerized Test

Model - Smart NGV490
PIC4